StoPowerwall ci with Sto Fireblocking
Insulated stucco wall systems with outbound graphite-enhanced expanded polystyrene or extruded polystyrene continuous insulation that incorporates a superior drainage plane and Sto Fireblocking to comply with 2022 NYC Building Code.
Additional System Characteristics
Allowable Deflection: L/360 ci Material: Sto GPS Board Available ci R-value R5.0 - R10 Typical wall thickness at minimum R-Value 2.25" (R5.0) Typical wall thickness at maximum R-Value 3.25" (R10) Construction Type I, II, III, IV, V Code Reports IAPMO ER 382, ICC ESR 1233, ICC ESR 2323 System NFPA 285 and Fire Resistance Compliance Max 2.125" Sto GPS Board Approximate weight 12 lbs / SF Service life, years >50 Sustainability Air and Moisture Barrier System StoGuard vapor permeable or impermeable system Defined drainage plane Yes Height Restrictions Fortification Layer: Available with Sto Crack Defense Fireblocking Includes Sto Fireblocking Cost $$
System Documents
System BulletinStoPowerwall ci 6300SpecificationsStoPowerwall ci 6300 DOC
StoPowerwall ci 6300 PDF
StoPowerwall AddendumBrochuresSto DrainScreen
StoSeal STPE Sealant
Sto GPS Board
Sto Fireblocking - Sales Sheet
Sto Crack DefenseDetailsStoPowerwall ci 63.xxFB Detail Booklet
StoPowerwall ci 63.xx Detail BookletCode & Test ReportsICC -ES Building Code: ESR-1233
NFPA 285 Wall System Compliance Directory